Process Control Error Conditions
SM Appendix 5-3 D037/D038/D040/D041
Appendix:
Process
Control Error
Conditions
No. Result Description Possible Causes/Action
1. Replace the development unit.
2. Replace the BCU board.
53
ID sensor
coefficient
(K5) detection
error
Not enough data can
be sampled.
Solid image is not sufficient density:
1. Retry the process control.
2. Replace the ID sensors.
3. Replace the BCU board.
Solid image is O.K.
1. Replace the ID sensors.
2. Replace the BCU board.
ID sensor is dirty:
1. Clean the ID sensors.
2. Retry the process control.
54
ID sensor
coefficient
(K5)
maximum/
minimum error
When the K5 is more
than the value of
SP3-362-003 or less
than the value of
SP3-362-004, the
error 54 is displayed.
ID sensor pattern density is too high
or low.
ID sensor or shutter is defective.
Same as 53
55
Gamma error:
Maximum
Gamma is out of
range. 5.0 < Gamma
ID sensor pattern density is too high.
Hardware defective.
Same as 53
56
Gamma error:
Minimum
Gamma is out of
range.
Gamma < 0.15
ID sensor pattern density is too low.
Hardware defective.
1. Same as 53
2. Replace the toner hopper unit.
57
Vk error:
Maximum
Vk is out of range.
150 < Vk
ID sensor pattern density is too low.
Hardware defective.
Same as 53
58
Vk error:
Minimum
Vk is out of range.
Vk < –150
ID sensor pattern density is too high.
Background dirty
Hardware defective