Troubleshooting Guide
D037/D038/D040/D041 6-6 SM Appendix
After Executing SP2-111-001
Result: "1" in SP2-194-007
Result: "5" (Out of adjustable range) in SP2-194-010, -011, -012
Test pattern check Possible cause/Countermeasure
Low image density on the output Low pattern density
Do the forced process control (SP3-011-001) or
supply some toner (SP3-015-xxx).
The main scan registrations of M,
C, Y are shifted by more than
±1.4 mm from the main scan
registration of K.
No defective component
Defective laser optics housing unit
Defective BCU
1. Do SP2-111-003 again.
2. Replace the laser unit.
3. Replace the BCU.
The sub scan registrations of M,
C, Y are shifted by more than
±1.4mm from the sub scan
registration of K.
No defective component
Defective image transfer belt
Defective drive units
Defective BCU
1. Do SP2-111-003 again.
2. Replace the image transfer belt.
3. Replace the drum motor.
4. Replace the BCU.
The main scan registration is
shifted by more than ±0.66 mm,
but only at the central area of the
image on the output.
Defective ID sensor at center
Deformed center area on the image transfer belt
Defective BCU
1. Replace the ID sensor.
2. Replace the image transfer belt.
3. Replace the BCU.
The skew for M, C, Y is more
than ± 0.75 mm from the main
scan registration of K. – at the
end of the scan line?
Defective PCDU
Defective laser unit
Defective BCU
1. Reinstall or replace the PCDU.

Table of Contents