EasyManua.ls Logo

Ricoh D037 - Page 550

Ricoh D037
1171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Service Mode
D037/D038/D040/D041 9-16 SM Appendix
Ends Temp. 4: –226 ENG
[-10 to 10 / -10 / 1 deg/step]
017
Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
Control Time 1: 226– ENG
[0 to 250 / 0 / 1 sec/step]
018
Specifies the start time of the temperature correction that is set with
SP1116-010 and -011.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 2: 226– ENG
[0 to 250 / 0 / 1 sec/step]
019
Specifies the start time of the temperature correction that is set with
SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 3: –226 ENG
[0 to 250 / 30 / 1 sec/step]
020
Specifies the start time of the temperature correction that is set with
SP1116-014 and -015.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 4: –226 ENG
[0 to 250 / 60 / 1 sec/step]
021
Specifies the start time of the temperature correction that is set with
SP1116-016 and -017.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
022 Center Temp.1:Duplex:226- ENG
023 Ends Temp.1:Duplex:226- ENG
024 Center Temp.2:Duplex:226- ENG
025 Ends Temp.2:Duplex:226- ENG
[-10 to 10 / 0 / 1 deg/step]