System Service Mode
SM Appendix 9-23 D037/D038/D040/D041
Appendix:
SP Mode
Tables
005 Plain:1200dpi:result *ENG
006 Thick:result *ENG
1902 [Drum Phase Adj.]
001 Execute -
[0 or 1 / 0 / 1]
Execute drum phase adjustment.
002 Result *ENG
[0 to 3 / 0 / 1]
Displays the result of drum phase
adjustment.
0: Successfully done
2: Sampling failure
3: Insufficient detection number
003 Auto Execution *ENG
[0 or 1 / 1 / 1]
Turns the automatic drum phase
adjustment on or off.
0: Off, 1: On
1907 [Inverter Timing Adj]
001 Inverter Position Adj. *ENG
[–10 to 10 / 0 / 1 mm/step]
[Feed Timing Adj]
002 R-Tray J-Gate SOL:ON *ENG
003 R-Tray J-Gate SOL:OFF *ENG
[–10 to 10 / 0 / 1 mm/step]
1950 [Fan Cooling Time Set]
001 Development Fan1 *ENG
002 Development Fan2 *ENG
003 Imaging Fan *ENG
[0 to 600 / 0 / 1sec/step]