EasyManua.ls Logo

Ricoh D037 - Page 580

Ricoh D037
1171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Service Mode
D037/D038/D040/D041 9-46 SM Appendix
2182
[Line Position Adj. Offset]
(Color) M. Scan: Main scan, S. Scan: Sub-scan
High / Medium: 120 mm/sec, Low: 60 mm/sec
001 C Magnification *ENG
002 M Magnification *ENG
003 Y Magnification *ENG
Adjusts the line position manually.
[-1 to 1 / 0 / 0.001%/step]
When line shifts are not corrected
by the automatic line position
adjustment, do this SP.
Increasing a value reduces the
image in the main scan direction.
Decreasing a value enlarges the
image in the main scan direction.
004 M. Scan: High: Dot: C *ENG
[-512 to 511 / 0 / 1 dot/step]
005 M. Scan: High: Subdot: C *ENG
[-15 to 15 / 0 / 1 pulse/step]
008 M. Scan: Low: Dot: C *ENG
[-512 to 511 / 0 / 1 dot/step]
009 M. Scan: Low: Subdot: C *ENG
[-15 to 15 / 0 / 1 pulse/step]
010 M. Scan: High: Dot: M *ENG
[-512 to 511 / 0 / 1 dot/step]
011 M. Scan: High: Subdot: M *ENG
[-15 to 15 / 0 / 1 pulse/step]
014 M. Scan: Low: Dot: M *ENG
[-512 to 511 / 0 / 1 dot/step]
015 M. Scan: Low: Subdot: M *ENG
[-15 to 15 / 0 / 1 pulse/step]
016 M. Scan: High: Dot: Y *ENG
[-512 to 511 / 0 / 1 dot/step]
017 M. Scan: High: Subdot: Y *ENG
[-15 to 15 / 0 / 1 pulse/step]
020 M. Scan: Low: Dot: Y *ENG
[-512 to 511 / 0 / 1 dot/step]
021 M. Scan: Low: Subdot: Y *ENG
[-15 to 15 / 0 / 1 pulse/step]
022 S. Scan: High: Dot: C *ENG
[-16384 to 16383 / 0 / 1 line]
023 S. Scan: High: Subdot: C *ENG
[–1 to 1 / 0 / 0.001 /line]
026 S. Scan: Low: Dot: C *ENG
[-16384 to 16383 / 0 / 1 line]

Table of Contents