System Service Mode
SM Appendix 9-51 D037/D038/D040/D041
Appendix:
SP Mode
Tables
Page: Standby: FC *ENG
[0 to 999 / 100 / 1 page/step]
007
Adjusts the threshold of the line position adjustment for BW printing mode in
stand-by mode. The line position adjustment is done when the number of
outputs in color printing mode reaches the value specified with this SP and the
condition of SP2-193-008 or SP2-193-009 is satisfied.
Temp Change *ENG
[0 to 100 / 5 / 1deg/step]
008
Adjust the temperature change threshold for the line position adjustment
(Mode b: adjustment once). The timing for line position adjustment depends on
the combinations of several conditions. Section Descriptions" section.
Elapse Time *ENG
[1 to 1440 / 300 / 1 minute/step]
009
Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions.
Temp Change 2 *ENG
[0 to 100 / 10 / 1deg/step]
011
Adjust the temperature change threshold for the line position adjustment
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions.
Elapse Time 2 *ENG
[1 to 9999 / 600 / 1 minute/step]
012
Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
016 Page: Power ON:BW+FC *ENG
[0 to 999 / 200 / 1 page/step]
2194 [MUSIC Exe Result] Line Position Adjustment: Execution Result
001 Year *ENG
[0 to 99 / 0 / 1 year/step]
002 Month *ENG
[1 to 12 / 1 / 1 month/step]
003 Date *ENG
[1 to 31 / 1 / 1 day/step]