System Service Mode
D037/D038/D040/D041 9-176 SM Appendix
[Digital Gain Adjust]
4632
Displays the gain value of the amplifiers on the controller for Green.
001 Latest: GE Color -
002 Latest: GO Color -
[0 to 1023 / 0 / 1 digit/step]
[Digital Gain Adjust]
4633
Displays the gain value of the amplifiers on the controller for Blue.
001 Latest: BE Color -
002 Latest: BO Color -
[0 to 1023 / 0 / 1 digit/step]
[Scan Adjust Error]
4645
Displays the gain value of the amplifiers on the controller.
001 Black Offset Corr 1 -
002 Black Offset Corr 2 -
[0 to 65535 / 0 / 1 digit/step]
[Read Hard Error]
4647
Displays the result of the SBU connection check.
001 Power-ON -
[0 to 65535 / 0 / 1 /step]
0: OK, Other: SBU connection check failure
If the SBU connection check fails, SC144
occurs.
4654
[Black Level Adj. Display]
RE: Red Even signal, RO: Red Odd signal
001
Last Correct Value: RE
Color
*ENG
Displays the black offset value (rough
adjustment) for the even red signal in the