SERVICE MODE TABLE
G104 5-22 SM
2105
[LD Power Cont.] LD Power Control
([Color], Process Speed) Process Speed -> LS: Low speed, RS: Regular speed
2105 001 [K] 0 *EGB
2105 002 [M] 0 *EGB
2105 003 [C] 0 *EGB
2105 004 [Y] 0 *EGB
Adjusts the LD power.
[10 to 200 / 100 / 1%/step] DFU
2105 009 [K] 0: LS *EGB
2105 010 [M] 0: LS *EGB
2105 011 [C] 0: LS *EGB
2105 012 [Y] 0: LS *EGB
Adjusts the LD power at low speed.
[10 to 200 / 100 / 1%/step] DFU
2109 [LD BeamPattern] LD Beam Pattern
2109 001 Picture Addition Adds the picture to the LD beam pattern.
[0 or 1 / 0 /-]
0: Not execute, 1: Execute
2109 002 Pattern Select Selects the LD beam pattern.
[0 to 24 / 0 / 1/step]
2109 004 Color Select Selects the color for the LD beam pattern.
[0 to 4 / 0 / 1/step]
2111 [Manual Execut.] Manual Execution
2111 001 Position Adjust. Performs the line position adjustment.
2111 002 Pro. Position Adj.
Performs an approximate line position
adjustment.
2111 003 Skew Adjust. Performs the skew adjustment.
2111 004 ID S. Adjust. Tests the ID sensor.
2120 [LD Off Check]
Displays the LD off check state.
2143
[ID S. Display] ID Sensor Display
The ID sensor assembly has three sensors: Left, Center, Right
2143 001 PWM: Left *EGB
2143 002 PWM: Center *EGB
2143 003 PWM: Right *EGB
Displays the PWM value for each sensor.
[0 to 512 / 0 / 1/step]
2143 004 Avg: Left *EGB
2143 005 Avg: Center *EGB
2143 006 Avg: Right *EGB
Displays the average output from each
sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 007 Max: Left *EGB
2143 008 Max: Center *EGB
2143 009 Max: Right *EGB
Displays the maximum output from each
sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 010 Min: Left *EGB
2143 011 Min: Center *EGB
2143 012 Min: Right *EGB
Displays the minimum output from each
sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 013 Max2: Left *EGB
2143 014 Max2: Center *EGB
Displays the maximum 2 output from each
sensor.