SERVICE MODE TABLE
SM 5-55 G104
Service
Tables
3577 005 AC: LS: [K] *EGB
3577 006 AC: LS: [M] *EGB
3577 007 AC: LS: [C] *EGB
3577 008 AC: LS: [Y] *EGB
[LD Control] LD Power Control
3581
Displays the current LD power rate for each mode.
3581 001 LD: RS: [K] *EGB
3581 002 LD: RS: [M] *EGB
3581 003 LD: RS: [C] *EGB
3581 004 LD: RS: [Y] *EGB
3581 005 LD: LS: [K] *EGB
3581 006 LD: LS: [M] *EGB
3581 007 LD: LS: [C] *EGB
3581 008 LD: LS: [Y] *EGB
[10 to 200 / 100 / 1%/step]
3701
[Low Resolution]
(Threshold, [Color])
SP 3701-001 controls if the pixel count is used in hybrid toner supply mode or
not. If this SP is ‘on’, it is used if the image coverage ratio for the page is below
a threshold value (if the coverage is above this ratio, then the TD sensor is
used). If this SP is ‘off’, then the TD sensor is always used.
SP3701-002 to 005 control the threshold values for the image coverage ratio.
3701 001 *EGB [0 to 1 / 0 / -]
0: Off, 1: On
3701 002 Threshold: [K] *EGB
3701 003 Threshold: [M] *EGB
3701 004 Threshold: [C] *EGB
3701 005 Threshold: [Y] *EGB
[0 to 100 / 1 / 1%/step]
3721 [Low Resolution] Toner Refresh Mode Setting in Low Image Coverage Ratio
3721 001 Toner Refresh Mode Enables or disables the toner refresh mode.
[0 or 1 / 0 / -]
0: On. 1: Off
3721 002 S: Toner Refresh
Toner refresh mode is done if the percentage
of pages that have low image coverage is
larger than this threshold value.
[0 to 50 / 20 / 1%/step]
3801 [TD Initial] TD sensor Initialization ([Color]) DFU
3801 001 [All]
3801 002 [Cl]
3801 003 [K]
3801 004 [M]
3801 005 [C]
3801 006 [Y]
Initializes the developer for each mode.
Press the Enter key to execute the
initialization after the machine asks
“Execute?”