ENGINE SERVICE MODE
SM 5-73 G104
Service
Tables
7803 017 R: PCU: [K] *EGB
7803 018 R: PCU: [M] *EGB
7803 019 R: PCU: [C] *EGB
7803 020 R: PCU: [Y] *EGB
7803 025 R: Trans Belt Unit *EGB
7803 026 R: T. Roll 2 *EGB
7803 027 R: Fusing Unit *EGB
Displays the number of revolutions of motors
or clutches for each current maintenance
unit.
[0 to 9999999 / 0 / 1 revolution/step]
When a unit is replaced, the machine
automatically detects that the new unit is
installed. Then, the current PM counter value
is automatically moved to the PM Counter -
Previous (SP7-906-11 to 20) and is reset to
“0”. The total number of revolutions made
with the last unit replaced can be checked
with SP7-906-11 to 20.
[0 to 9999999 / 0 / 1 rotation/step]
7803 033 Toner Supply: [K] *EGB
7803 034 Toner Supply: [M] *EGB
7803 035 Toner Supply: [C] *EGB
7803 036 Toner Supply: [Y] *EGB
Displays the number of sheets printed until
the waste toner bottle becomes full or toner
runs out.
[0 to 9999999 / 0 / 1 /step]
7803 037 R%: PCU: [K] *EGB
7803 038 R%: PCU: [M] *EGB
7803 039 R%: PCU: [C] *EGB
7803 040 R%: PCU: [Y] *EGB
7803 045 R%: Trans Belt Unit *EGB
7803 046 R%: T. Roll 2 *EGB
7803 047 R%: Fusing Unit *EGB
Displays the value given by the following
formula:
(Current revolution ÷ Target revolution) ×
100, where “Current revolution” is the current
value for the counter of the part, and “Target
revolution” is the values of SP7-803-17
through 27. This shows how much of the
unit’s expected lifetime has been used up.
The R% counter is based on rotations, not
prints. If the number of rotations reaches the
limit, the machine enters the end condition
for that unit. If the print count lifetime is
reached first, the machine also enters the
end condition, even though the R% counter
is still less than 100%.
[0 to 999 / 0 / 1 rotation%/step]
[PM Count. Reset] Preventive Maintenance Counter Reset
(Sheets, Unit, [Color]) Trans Belt Unit: Transfer Belt Unit, T. Roll 2: Transfer
Roller 2, Waste Toner: Waste Toner Bottle, Toner: Toner Bottles
7804
Clears the PM counter for each unit.
7804 002 PCU: [K] -
7804 003 PCU: [M] -
7804 004 PCU: [C] -
7804 005 PCU: [Y] -
7804 009 Trans Belt Unit -
7804 010 Transfer Roller 2 -
7804 011 Fusing Unit -
7804 012 S: By-pass -
7804 013 S: Tray 1 -
7804 014 S: Tray 2 -
7804 015 S: Tray 3 -
7804 017 S: Toner: [K] -
7804 018 S: Toner: [M] -
Clears the PM counter.
Press the Enter key after the machine asks
“Execute?”.
When a unit is replaced, the machine
automatically detects that the new unit is
installed. Then, the current PM counter value
is automatically moved to the PM Counter-
Previous (SP7-906-1 to 40) and is reset to
“0”.