LASER EXPOSURE
SM 6-33 G104
Detailed
Descriptions
Interrupt
If SP 2153-005 is set to ‘on’, then the adjustment is done when the one of the
following conditions occurs during a print job with many pages.
• When the number of printed pages after the previous adjustment becomes
more than a set number. The number of pages includes black and color printing.
The default value is 190 pages. (If this condition occurs, automatic line position
adjustment after the next interval process control will not be cancelled.)
You can adjust the default value with SP2153-010.
• When the temperature changed after a previous adjustment by more than a set
value. The default value is 5 °C.
You can adjust the temperature change value with SP2153-012.
• When the magnification changed after a previous adjustment by more than a
set value. The default value is1 %.
You can adjust the magnification change value with SP2153-015.
This table shows when the automatic line position adjustment is done. It also
shows the main SPs that control the timing of the adjustment. If SP 2153 001 is ‘off’,
then the automatic adjustment is never done. Note that the adjustments for the
sub-scan line position, main scan line position, and magnification are done at the
same time.
Enabled/Disabled
(SP 2153 001)
After
Process
Control
(SP 2153
002)
Initialization
(SP 2153
003)
Printing
(SP 2153
004)
Interrupt
(SP 2153
005)
Remarks
On Default ON
Off
On
On
Off
Off
On ON
Off
On
ON
Off
Off
Off
On ON
Off
On
On
Off
Off
On ON
Off
On
On
Off
Off
Off
Off
Off
-
-
-
-
No
Adjustment
NOTE: You can also do the automatic line position adjustment manually with
SP2111-001.