EasyManua.ls Logo

Ricoh G104 - Page 96

Ricoh G104
601 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE CALL CONDITIONS
G104 4-12 SM
Item
SC
[Level]
Symptom Possible Cause/Required Action
Fan motor error 532
[D]
The fan motor “On” signal is
not detected for the
components below after the
drum motor for black is set
to “On”.
PSU fan
Fusing unit fan
Polygon motor fan
Drive unit fan
Exit paper fan
Defective fan motor
1. If the error occurs again, one of the fans is
defective. Remove the covers, find the defective
fan and replace it.
Thermistor error 541
[A]
The thermistor output is
less than 0°C for six
seconds.
Disconnected thermistor
Defective connector connection
Print ready temperature error 542
[A]
1. The heating roller
temperature increase
that is less than 67
degrees for 9 seconds
is detected five times
consecutively.
2. The fusing temperature
does not reach the print
ready temperature
within 15 seconds after
the fusing lamp was
controlled.
Defective thermistor
Thermistor coming off
Incorrect power supply input at the main power
socket
Defective fusing lamp
High temperature detection: Software 543
[A]
The thermistor detects
230°C for 0.2 seconds.
Defective thermistor
Defective I/O board
Defective EGB
High temperature detection: Hard 544
[A]
The thermistor detects
250°C.
Defective thermistor
Defective I/O board
Defective EGB
Defective fusing unit, PSU, or EGB
1. Replace the fusing unit.
2. Replace the PSU.
Heating lamp error 545
[A]
The fusing lamp is full-
powered for 8 seconds after
the heating roller reaches
the print ready temperature.
Deformed thermistor
Thermistor coming off
Defective fusing lamp
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA

Table of Contents

Related product manuals