Service Mode Table
SM 5-15 G133
Service
Tables
[Fusing Temperature] Fusing Temperature Adjustment
1105
The following SPs (SP1105) are related to fusing temperature control. For
more details, refer to "Fusing Temperature Control" in the "Detailed Section
Descriptions" chapter.
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, Pressure –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
Fusing Ready Temp. *ENG
[100 to 200 / 138 / 1°C/step]
001
Specifies the heating roller target temperature for the ready condition.
Fusing Ready: Offset *ENG
[0 to 100 / 0 / 1°C/step]
002
Sets the heating roller offset temperature for the printing ready condition.
Ready temperature = (Target temperature specified in SP1-105-1) –
Temperature specified in this SP mode
Ends Ready: Offset *ENG
[70 to 180 / 70 / 1°C/step]
003
Sets the heating roller offset temperature at the end of the heating roller. This
value is one of the thresholds to determine if the machine is at the heating roller
target temperature during warm-up.
Ends Ready: Upper Limit *ENG
[0 to 200 / 200 / 1°C/step]
004
Sets the upper limit temperature of the heating roller at the end of the heating
roller. This value is one of the thresholds to determine if the machine is at the
heating roller target temperature during warm-up.
Pressure Ready: Offset. * ENG
[40 to 180 / 90/ 1°C/step]
005
Sets the pressure roller offset temperature. This value is one of the thresholds
to determine if the machine is at the heating roller target temperature during
warm-up.
Pressure Ready: Upper
Limit.
* ENG
[0 to 180 / 180 / 1°C/step]
006
Sets the limit temperature of the pressure roller. This value is one of the
thresholds to determine if the machine is at the heating roller target