Service Mode Table
G133 5-16 SM
temperature during the warm-up.
Stand-By: Pressure * ENG
[90 to 150 / 150 / 1°C/step]
012
Specifies the stand-by temperature for the pressure roller.
Pressure Target Energy
Saver
* ENG
[90 to 150 / 140 / 1°C/step]
016
Specifies the temperature during the panel-off mode for the pressure roller.
The following SPs except SP1105-085 set the target operating temperatures of
the heating roller in various modes.
030 Plain: FC: Simplex *ENG
032 Plain: FC: Duplex *ENG
034 Plain: BW: Simplex *ENG
036 Plain: BW: Duplex *ENG
[100 to 200 / 160 / 1°C/step]
038 Thin: FC: Simplex *ENG
040 Thin: FC: Duplex *ENG
042 Thin: BW: Simplex *ENG
044 Thin: BW: Duplex *ENG
[100 to 200 / 150 / 1°C/step]
046 Thick 1: FC: Simplex *ENG
048 Thick 1: FC: Duplex *ENG
050 Thick 1: BW: Simplex *ENG
052 Thick 1: BW: Duplex *ENG
[100 to 200 / 170 / 1°C/step]
054 Thick 2: FC: Simplex *ENG
055 Thick 2: BW: Simplex *ENG
[100 to 200 / 170 / 1°C/step]
056 OHP: FC *ENG
[100 to 180 / 165 / 1°C/step]
057 OHP: BW *ENG
[100 to 180 / 160 / 1°C/step]

Table of Contents