Service Mode Table
SM 5-19 G133
Service
Tables
Extra Rotation Temp.: H *ENG
[100 to 200 / 160 / 1°C/step]
108
Specifies the target temperature for extra idling mode in a high temperature
environment. The high temperature threshold can be adjusted with
SP1112-004.
111 Thick: Small Size *ENG
[100 to 170 / 155 / 1°C/step]
113 Thick4:FC:Simplex *ENG
114 Thick4:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
115 Thick5:FC:Simplex *ENG
116 Thick5:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
117 Thick6:FC:Simplex *ENG
118 Thick6:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
119
PF/PS Temp.: Extend:
O/V: Plain: FC Prn
*ENG
[0 to 100 / 10 / 1°C/step]
120
PF/PS Temp.: Extend:
O/V: M-Thick
*ENG
[0 to 100 / 5 / 1°C/step]
121
PF/PS Temp.: O/V:
Stand-By: Mid-Thick
*ENG
[0 to 100 / 5 / 1°C/step]
122
PF Temp: Pressure:
Plain
*ENG
[10 to 150 / 20 / 1°C/step]
123 PF Temp: Pressure:
Plain: FC Prn.
*ENG
[10 to 150 / 90 / 1°C/step]
124 PF Temp: Pressure:
M-Thick: BK
*ENG
125
PF Temp: Pressure:
M-Thick: FC
*ENG
[10 to 150 / 124 / 1°C/step]
126
Reload Correction
Temp.: Plain: Reload
*ENG
[0 to 20 / 10 / 1°C/step]
⇒
⇒
Rev. 01/2007