EasyManua.ls Logo

Ricoh G133 - Page 341

Ricoh G133
993 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Mode Table
SM 5-19 G133
Service
Tables
Extra Rotation Temp.: H *ENG
[100 to 200 / 160 / 1°C/step]
108
Specifies the target temperature for extra idling mode in a high temperature
environment. The high temperature threshold can be adjusted with
SP1112-004.
111 Thick: Small Size *ENG
[100 to 170 / 155 / 1°C/step]
113 Thick4:FC:Simplex *ENG
114 Thick4:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
115 Thick5:FC:Simplex *ENG
116 Thick5:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
117 Thick6:FC:Simplex *ENG
118 Thick6:BW:Simplex *ENG
[100 to 180 / 170 / 1°C/step]
119
PF/PS Temp.: Extend:
O/V: Plain: FC Prn
*ENG
[0 to 100 / 10 / 1°C/step]
120
PF/PS Temp.: Extend:
O/V: M-Thick
*ENG
[0 to 100 / 5 / 1°C/step]
121
PF/PS Temp.: O/V:
Stand-By: Mid-Thick
*ENG
[0 to 100 / 5 / 1°C/step]
122
PF Temp: Pressure:
Plain
*ENG
[10 to 150 / 20 / 1°C/step]
123 PF Temp: Pressure:
Plain: FC Prn.
*ENG
[10 to 150 / 90 / 1°C/step]
124 PF Temp: Pressure:
M-Thick: BK
*ENG
125
PF Temp: Pressure:
M-Thick: FC
*ENG
[10 to 150 / 124 / 1°C/step]
126
Reload Correction
Temp.: Plain: Reload
*ENG
[0 to 20 / 10 / 1°C/step]
Rev. 01/2007

Table of Contents