Service Mode Table
G133 5-20 SM
127
Reload Correction
Temp.: M-Thick: Reload
*ENG
[0 to 20 / 15 / 1°C/step]
128
Reload Correction
Temp.: M-Thick: Standby
*ENG
[0 to 20 / 10 / 1°C/step]
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Fusing: Center -
002 Fusing: Ends -
003 Pressure -
[–20 to 250 / - / 1°C/step]
The heating roller has two lamps. One
heats the center of the heating roller and
the other heats both ends of the heating
roller.
[Forced Ready Setting]
1108
Japan use only
001 ON/OFF *ENG
[0 or 1 / 0 / - ]
0: OFF, 1: ON
002 Target Voltage Ratio *ENG
[85 to 100 / 92 / 1%/step]
003 Measured Voltage Ratio *ENG
[70 to 120 / 100 / 1%/step]
004 Target Temperature *ENG
[110 to 155 / 155 / 1 deg/step]
1109 [Fusing Nip Band Check]
001 Execute -
Executes the nip band measurement
between fusing belt and pressure roller.
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.