Service Mode Table
SM 5-21 G133
Service
Tables
Pre-Idling Time *ENG
[0 to 120 / 240 / 1 sec/step]
002
Specifies the fusing rotation time before executing SP1109-001.
Stop Time * ENG
[5 to 30 / 10 / 1 sec/step]
003
Specifies the time for measuring the nip.
1112 [Environmental Correction: Fusing]
Temp.: Threshold: Low *ENG
[10 to 23 / 17 / 1°C/step]
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High *ENG
[24 to 40 / 30 / 1°C/step]
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction *ENG
[0 to 15 / 5 / 1°C/step]
003
Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of
this SP is added to the heating roller temperature.
High Temp. Correction *ENG
[0 to 15 / 0 / 1°C/step]
004
Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of
this SP is subtracted from the heating roller temperature.
1113 [Stand-by Time]
Shift Time *ENG
[0 to 180 / 60 / 1 sec/step]
001
Specifies the interval from the ready mode to the stand-by mode.
If the machine does not do any printing job for the time specified with this SP
after the heating roller has reached the ready temperature, the machine
returns to the stand-by mode.
002 Recovery Target Temp. *ENG
[0 to 180 / 10 / 1 sec/step]