Service Mode Table
G133 5-186 SM
[Last PCU Mt: K] Last Drive PCU Motor: K
3513
Displays the last time that the PCU motors stopped.
These are used for process control execution timing.
001 Year *ENG
[0 to 99 / 0 / 1/step]
002 Month *ENG
[1 to 12 / 1 / 1/step]
003 Date *ENG
[1 to 31 / 1 / 1/step]
004 Hour *ENG
[0 to 23 / 0 / 1/step]
005 Minute *ENG
[0 to 59 / 0 / 1/step]
[Environment: Job End]
3514
Displays the environmental conditions for the last job.
These are used for process control execution timing.
001 Temperature *ENG
[-1280 to 1270 / - / 0.1°C/step]
002 Relative Humidity *ENG
[0 to 1000 / - / 0.1%RH/step]
003 Absolute Humidity *ENG
[0 to 1000 / - / 0.1 g/cm
3
/step]
[Execution Interval: Display]
3515
Displays the current interval for process control execution.
When the machine calculates the timing for process control, it uses a number
of conditions. These are the results after considering all the conditions.
001 Job End: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step]
002 Job End: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step]
003 Interrupt: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step]
004 Interrupt: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step]
3516 [Refresh Mode] DFU