EasyManua.ls Logo

Rlide R2 Series - Page 135

Default Icon
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
133
b.
In 1Sec.Key menu, press [1] to enter
[MSR] setting.
[1]
1 Sec.key
1.[MSR]
>>Set
2.[Disp]
Meas 1/2
3.[User]
Meas Para
4.[SO]
5.[Data]
c.
There are two [MSR] keys,
corresponding to [MSR1] and [MSR2]
keys under the screen. Each key has its
own setting, select the MSR keys which
need to set meas mode. Then press
[ENT] (or press numeric key [1] or [2]
directly.)
[1] or [2]
Meas Mode
1. Meas 1
2. Meas 2
d.
Each [MSR] key has 4 settings.
In the “Const” item, use numeric keys to
input values. In the other items, use [ ]/
[ ] to change the settings. 1)
[ ]/[ ]
+
[]/[]
<Meas1>
TGT:
Prism
Const:
-30mm
Mode:
Fine[s]
Rec:
All
e.
After setting, press [ENT] to return to 1
Sec.Key menu.
[ENT]
1 Sec.key
1.[MSR]
>>Set
2.[Disp]
Meas 1/2
3.[User]
Meas Para
4.[SO]
5.[Data]
1) You can also access the settings screen by holding down [MSR1] or [MSR2] for one second.
11.5.2 [DISP] Key Settings
To change the display items in the basic measurement screen, and in SO observation screen, press [2.
Disp] in the 1Sec. key menu.
STEP
OPERATION
DISPLAY
a.
In 1 Sec. key menu, press [2] to enter to
[Disp] setting.
[2]
1 Sec.key
1.[MSR]
2.[Disp]
>>Change
3.[User]
Display
4.[SO]
Meas&SO
5.[Data]

Table of Contents