24
b.
Input note and then press [ENT]. The
instrument returns to the basic
measurement screen.
Input Note
Input Note
1
OK
3.4 START SURVEY
After finishing all settings, you can start surveying. The survey result is displayed in 4 pages including all
data of routine survey. Press DSP to view. If the 2nd unit is set, a HD/VD/SD screen will appear.
Please set a job, station and backsight azimuth before measurement.
STEP
OPERATION
DISPLAY
a.
Collimate to the center of target prism,
press [MSR1] or [MSR2].
[MSR1]/
[MSR2]
Display
1/4
HA#
30°2150”
VA#
273°1345
SD#
PT:1
HT:
1.000m
b.
While the instrument is taking a
measurement, the prism constant is
displayed in a small font.
Display
1/4
HA#
30°2150”
VA#
273°1345
SD#
<-30mm>
PT:1
HT:
1.000m
c.
Display the result of measurement in
four pages, including all normal
measure functions such as measure of
angle, distance and coordinate, etc.
Press [DSP] or []/[] to view each
page.
*If the secondary distance unit is set,
another page will display.
DSP
or
[]/[]
First page:
Display
1/4
HA#
30°2150”
VA#
273°1345
SD#
2.201m
PT:1
HT:
1.000m
Second page:
Display
2/4
AZ#
30°2150”
HD#
2.274m
VD#
-0.185m
PT:1
HT:
1.000m