23
b.
Press []/[] or numeric keys [1][5]
to select target set, and then press
[ENT]. To edit the target set, highlight
the target set and press Edit. After
editing, press [ENT] 1)
[]/[]
+
[Edit]
1<N,0, 1.000>
<S,0, 1.000>
3<N,0, 1.000>
4<P,0, 2.000>
5<N,0, 1.000>
Edit
Set
Press [Edit]:
<TGT1>
TGT:
Non-prism
Const:
-30mm
HT:
1.000m
c.
The system starts the set target set, and
returns to BMS.
Display
1/5
HA#
30°2150
VA#
273°1345
SD#
PT:1
HT:
1.000m
1)Type=prism/non prism/reflector sheet
Constant=-999 - 999mm
HT=-9999.999 - 9999.999mm
HTcan be left blank in the target set (input the number beyond the max instrument height), the current HT value
is always applied to the measurement.
3.3.4 Enter a Field Note
To enter a field note, press [HOT] and then press [4]. This function can be used at any time on any
observation screen. Each note can be up to 50 characters. The note is stored as a CD record in the raw
data.
STEP
OPERATION
DISPLAY
a.
In HOT Key menu press numeric key
[4] to enter Note function.
[4]
HOT Key
1.Input HT
2.Temp&Pres
3.TGT
4.Note