139
vertical line.
As illustrated,A′offsets from the center to the cross hair tilts, then need to adjust the reticle.
Adjust
1. If the object A does not move along with the vertical line, firstly remove the eyepiece cover to expose the
three or four reticle adjusting screws.
2. Loosen all the reticle adjusting screws uniformly with an adjusting pin. Rotate the reticle around the sight
line and align the vertical line of the reticle with pointA’.
3. Tighten the reticle adjusting screws uniformly. Repeat the inspection and adjustment to see if the
adjustment is correct.
4. Replace the eyepiece cover.
12.4 PERPENDICULARITY BETWEEN LINE OF SIGHT AND HORIZONTAL AXIS
(2C)
Check
1. Set object A at about 100 meters away the same height as the instrument, and make the vertical angle
with ± 3° . Then level and center the instrument and turn on the power
2. Sight object A in FaceI and read the horizontal angle value. (e.g.: Horizontal angle L=10°13′10″).
3. Loosen the vertical and horizontal clamp screws and rotate the telescope. Sight object A in FaceⅡand
read the horizontal angle value. (e.g.: Horizontal angle R= 190°13′40″).
4. 2C=L-R± 180° =-30″≥±20″, adjustment is necessary.
Adjust
A. Electronic Adjustment Operation Steps
:
a.
After leveling the instrument, press
[MENU] to enter into the menu, press [7]
(or [▼] + [ENT]) to enter Adjustments.