a.
In [Offset] menu, press [3] to enter the
2Prism Pole function.
b.
Sight the first prism and press
[MSR1]/[MSR2].
Sight the first
prism
[MSR1]/
[MSR2]
c.
Program enter measuring the second
point automatically. Sight the second
prism and press [MSR1]/[MSR2].
Sight the second
prism
[MSR1]/
[MSR2]
d.
Enter the distance between the second
prism and the target point. Alternatively,
if you don’t need QA information, you
can leave the distance between the first
and the second prism blank.
e.
If you entered a P1-P2 distance, the QA
screen appears. Compare the entered
value and the measured distance to
check the accuracy of the observation.
To reinput the distances, press [Redo] to
return to Step d. To confirm, please
press [OK] or [ENT] to Step f.
f.
Press [ENT] to record the point.
Sample of records:
CO,2Prism O/S: