61
6.3 TWO-PRISM POLE
STEP
OPERATION
DISPLAY
a.
In [Offset] menu, press [3] to enter the
2Prism Pole function.
[3]
Offset
1. O/S Dist
2. O/S Ang.
3. O/S 2D
4. +HA Line
5. Input HD
b.
Sight the first prism and press
[MSR1]/[MSR2].
Sight the first
prism
[MSR1]/
[MSR2]
O/S 2D
<No.1>
1/5
HA#
15°4213
VA#
94°0113
SD#
* Sight Press [MSR]
OK
c.
Program enter measuring the second
point automatically. Sight the second
prism and press [MSR1]/[MSR2].
Sight the second
prism
[MSR1]/
[MSR2]
O/S 2D
<No.2>
1/5
HA#
43°1914
VA#
91°1147
SD#
* Sight Press [MSR]
OK
d.
Enter the distance between the second
prism and the target point. Alternatively,
if you don’t need QA information, you
can leave the distance between the first
and the second prism blank.
Input distances
Input Dist
P1-p2:
5.000m
1
P2-TGT:
2.000m
* P1-P2 May Omit
e.
If you entered a P1-P2 distance, the QA
screen appears. Compare the entered
value and the measured distance to
check the accuracy of the observation.
To reinput the distances, press [Redo] to
return to Step d. To confirm, please
press [OK] or [ENT] to Step f.
P1-P2
Dist
InputDis
5.000m
Meas Dis
5.005m
Redo
OK
f.
Press [ENT] to record the point.
[ENT]
Rec Pt
PT:
26
A
HT:
1.000m
CD:
List
Stac
Sample of records:
CO,2Prism O/S:

Table of Contents