65
f.
Enter a PT (and CD) value and press
[ENT], The target point is calculated and
recorded as an SS record.
Enter PT and
CD
[ENT]
Rec Pt
PT:
26
A
HT:
1.000m
CD:
List
Stac
6.7 COLUMN
STEP
OPERATION
DISPLAY
a.
In Page 2 of [Offset] menu, press [7] to
enter Column function.
[7]
Offset
1. CornerPt
2. Column
3. InputdSD
b.
If you havet taken a measurement to the
column before entering to this function, a
temporary measuring screen appears.
Sight any point on the surface of the
column and press [MSR1]/ [MSR 2].
Sight any point
on the surface of
the column
[MSR1]/
[MSR2]
HA#
47°4213
VA#
94°0113
SD#
HT:
1.000m
* Sight Press [MSR]
HT
OK
c.
Press [ENT]. If you use a prism attached
to the surface of the column for the
distance measurement, press the +SD
softkey to eliminate the offset error (from
the attached point to the measured
surface of the prism) before you press
[ENT].
[ENT]
HA#
47°2514
VA#
94°5615
SD#
3.635m
HT:
1.000m
* Input +SD/Press [ENT]
+SD
Press+SD
Column
HA#
47°2514
VA#
94°5615
SD:
3.635m
+SD:
0.000m
d.
Sight one edge of the column.
Sight one edge
of the column
HA#
80°3213
VA#
94°56’15
* Sight
1
Calc
OK