e.
Enter combination of distance offset to
specify the point.
After entering one item, press [ENT]
moving to the next.
Enter
combination of
distance offset to
specify the point.
f.
The calculated coordinates are shown.
Enter a PT and CD value, press [ENT] to
record. The display returns to BMS. ※1)
※1) Raw data is also recalculated, based on the distance offset value.
6.2 MEASURING ANGLE OFFSETS
a.
In [Offset] menu, press [2] to enter angle
offset function
b.
If you have not taken a distance
measurement before entering this
function, a temporary measurement
screen appears. Sight the target and
press [MSR 1]/[MSR 2].
c.
The measuring results are shown.
Press [DSP] or [▼] to view each dialog
box of the results.
d.
To take the angle offset, rotate the
alidade and telescope. The measured
distance (HD) remains unchanged.