c.
Input the second point on the vertical
plane, and press [ENT].
d.
Once the plane is defined, the calculated
Sta and dZ values are updated as you
move the telescope. No distance
measurement is required.
STA:Horizontal distance from P1 to
the target point along the baseline
dZ: Vertical distance from P1 to the
target point
Press [▼] to display other pages. As
shown in the right graph.
e.
To record the point, press [ENT] on any
screen. Input PT and CD and then press
[ENT] in the dialog box shown as the
right graph.
※1) About method to input PtID, please refer to “2.8 METHOD TO INPUT PTID”.
7.6 3-PT REFERENCE PLANE (S-PLANE)
Measuring distance and offset values on the slope.