EasyManua.ls Logo

Rlide R2 Series - Page 40

Default Icon
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
e.
Enter the target height and press [ENT].
Enter the target
height
+
[ENT]
Input PT01
PT:
1
1
HI:
1.800m
CD:
List
Stac
f.
Sight the center of first target prism on
F1and press [MSR1] or [MSR2] to start
survey. If only need to measure angle,
press [ENT].
If the horizontal circle is on Face-2,
screen would displayTurn to F1. As
show in the right graph. Rotate the
telescope and alidade, and sight the BS
point in Face-1.
Sight
+
[MSR1]/
[MSR2]
RESE <Sight 01>
HA#
30°2150”
HD#
SD#
* Press [MSR]/[ENT]
F2
1
* Turn to F1
g.
The measuring result is displayed, press
[ENT].
To measure the backsight point on
F2press [F2] softkey. Rotate the
telescope and alidade, and sight the
center of target prism, and press
[MSR1] or [MSR2]. Press [ENT] after
measuring.
[ENT]
RESE <Sight 01>
HA#
30°2150”
HD#
2.032m
SD#
2.040m
* Press [ENT] Next
F2
F2
Stn Setup
1/2
HA:
30°2150”
* Turn to F2
* Press [ENT] Next
h.
If measured on F1 and F2, a QA screen
appears, press [OK] or
[ENT] to record the result.
[OK]
or
[ENT]
Stn Setup
1/2
dHA:
0°0005
dVA:
-0°0001
dSD:
0.001m
* Press [ENT] Rec
Abrt
CP
OK

Table of Contents