170 Rockwell Automation Publication 2198-UM005C-EN-P - February 2022
Appendix A Interconnect Diagrams
Power Wiring Examples You must supply input power components. The single-phase and three-phase
line filters are wired downstream of the circuit protection.
Figure 79 - Kinetix 5300 Drives Power Wiring (three-phase operation)
L3
L2
L1
24V–
24V+
2
1
MBRK -
MBRK +
4
3
2
1
MBRK -
MBRK +
U
V
W
2
1
4
3
2
1
DC+
SH
170…253V AC rms or
342…528V AC rms
Three-phase Input
Note 1
Bonded Cabinet Ground Bus *
Control Power
PE Ground
AC Input Power
Connector
Circuit Protection *
Note 2
* Indicates Customer Supplied Component
2198-C1004-ERS, 2198-C1007-ERS,
2198-C1015-ERS, 2198-C1020-ERS,
2198-C2030-ERS, 2198-C2055-ERS,
2198-C2075-ERS, 2198-C4004-ERS,
2198-C4007-ERS, 2198-C4015-ERS,
2198-C4020-ERS, 2198-C4030-ERS,
2198-C4055-ERS, 2198-C4075-ERS
Chassis
Note 4
Customer Supplied
+24V DC
Power Supply *
Motor Brake
Connector
Three-phase
Motor Power
Connections
Note 8
Motor Power
Connector
Cable Shield
Clamp
Refer to table on page 169
for note information.
Shunt
Connector
Motor Brake
Connections
2198-DBxxx-F
Three-phase
AC Line Filter
Note 3
Internal Shunt
Note 7

Table of Contents

Other manuals for Rockwell Automation 2198-C4015-ERS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation 2198-C4015-ERS and is the answer not in the manual?

Rockwell Automation 2198-C4015-ERS Specifications

General IconGeneral
BrandRockwell Automation
Model2198-C4015-ERS
CategoryServo Drives
LanguageEnglish

Related product manuals