Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
230User Manual 1173.9240.02 ─ 17
Parameters:
<State> ON | OFF
*RST: OFF
Example:
DIAG:SERV:NSO ON
Manual operation: See "Noise Source" on page 122
OUTPut:ADEMod[:ONLine][:STATe] <State>
This command enables or disables online demodulation output to the IF/VIDEO/
DEMOD output connector on the rear panel of the R&S FSW.
Parameters:
<State> ON | OFF
*RST: OFF
Example:
OUTP:ADEM ON
Manual operation: See "Online Demodulation Output State" on page 124
OUTPut:ADEMod[:ONLine]:SOURce <WindowName>
This command selects the result display whose results are output. Only active time
domain results can be selected.
Parameters:
<WindowName> <string>
String containing the name of the window.
By default, the name of a window is the same as its index. To
determine the name and index of all active windows, use the
LAYout:CATalog[:WINDow]? query.
FOCus
Dynamically switches to the currently selected window. If a win-
dow is selected that does not contain a time-domain result dis-
play, the selection is ignored and the previous setting is main-
tained.
Example:
OUTP:ADEM:ONL:SOUR 'AnalogDemod'
OR:
DISP:WIND1:SEL
OUTP:ADEM:SOUR FOC
Manual operation: See "Output Selection" on page 124
OUTPut:ADEMod[:ONLine]:AF[:CFRequency] <Frequency>
This command defines the cutoff frequency for the AC highpass filter (for AC coupling
only, see [SENSe:]ADEMod<n>:AF:COUPling on page 255).
Configuring the Measurement