Parameters:
<Boolean> ON | OFF
Display or hide the information elements.
Example:
SYSTem:DISPlay:BAR:TOOLs ON; STOols ON; STATus
ON
Display the toolbar, softtool panel, and status bar.
SYSTem:DISPlay:BAR:TITle OFF; HKEY OFF; MENU
OFF
Hide the title bar, hardkey bar, and menu bar.
Manual operation: See "Tool Bar" on page 669
SYSTem:DISPlay:COLor
<ColorScheme>
Selects the color scheme for all diagram areas in the active recall set.
Parameters:
<ColorScheme> DBACkground | LBACkground | BWLStyles | BWSolid
DBACkground - dark background
LBACkground - light background
BWLStyles - black and white line styles
BWSolid - black and white solid
Example:
SYST:DISP:COL LBAC
Independent of the selected color scheme, hardcopies are
always generated with the light background scheme.
Manual operation: See "Color Scheme" on page 662
SYSTem:DISPlay:CONDuctances <Boolean>
Changes the presentation of "capacitance C<i> in parallel with resistance R<i>" circuit
blocks in lumped de/embedding networks.
Parameters:
<Boolean> ON - display conductances
OFF - display capacitaces
Manual operation: See "Conductance in Embedding Networks" on page 677
SYSTem:DISPlay:DIALogs:SETup:MCAL[:STATe] <Boolean>
Enables/disables multiple calibrations in the calibration wizard.
Parameters:
<Boolean>
Manual operation: See "Multiple Cal in Calibration Wizard" on page 675