EasyManua.ls Logo

Rohde & Schwarz R&S ZNB - Page 790

Rohde & Schwarz R&S ZNB
1451 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
790User Manual 1173.9163.02 ─ 53
Parameters:
<EyeView> STIMulus | EMPHasis | JITTer | NOISe | DUT | EQUalization
The rightmost building block that shall be part of the calculation
chain STIMulus > EMPHasis > JITTer > NOISe > DUT > EQUali-
zation.
Note that the selected block must be active, for example
CALCulate1:EYE:VIEW JITTER requires
CALCulate<Chn>:EYE:JITTer:STATe to be ON.
Conversely, if CALCulate1:EYE:VIEW is set to JITTER and
subsequently CALCulate1:EYE:JITTer:STATe is turned
OFF, the calculation chain is further shortened to the next active
building block.
Options:
R&S ZNB/ZNBT-K20
Manual operation: See "[Slider]" on page 624
8.3.1.6 CALCulate:FILTer[:GATE]...
The CALCulate:FILTer[:GATE]... commands define the properties of the time
gate which is used to optimize the time domain response.
CALCulate:FILTer[:GATE]:TIME:AOFFset.........................................................................790
CALCulate<Chn>:FILTer[:GATE]:TIME[:TYPE]..................................................................791
CALCulate<Chn>:FILTer[:GATE]:TIME:CENTer.................................................................791
CALCulate<Chn>:FILTer[:GATE]:TIME:DCHebyshev......................................................... 792
CALCulate<Chn>:FILTer[:GATE]:TIME:SHAPe..................................................................792
CALCulate<Chn>:FILTer[:GATE]:TIME:SHOW.................................................................. 793
CALCulate<Chn>:FILTer[:GATE]:TIME:SPAN....................................................................793
CALCulate<Chn>:FILTer[:GATE]:TIME:STARt...................................................................794
CALCulate<Chn>:FILTer[:GATE]:TIME:STOP................................................................... 794
CALCulate<Chn>:FILTer[:GATE]:TIME:STATe................................................................... 794
CALCulate<Chn>:FILTer[:GATE]:TIME:WINDow............................................................... 795
CALCulate:FILTer[:GATE]:TIME:AOFFset <Boolean>
Activates the operating mode where the time gate is moved in the opposite direction
when the "Delay" setting is changed.
Parameters:
<Boolean> ON | OFF - enable or disable "Adjust Time Gate".
*RST: OFF
SCPI Command Reference

Table of Contents

Related product manuals