Digital Standard PDC SMIQ
1125.5555.03 2.290 E-9
RATE
CONFIGURATION...
Opens a window for determining which slots in the frame are to be configured
as half-rate and full-rate channels. Full-rate channels occupy two slots in a
frame, the second slot is fully determined by the configuration of the first slot.
The following eight combinations can be selected:
Selection Full-rate slots Half-rate slots
ALL HALF keine 0, 1, 2, 3, 4, 5
FULL 1 0 + 3 1, 2, 4, 5
FULL 2 1 + 4 0, 2, 3, 5
FULL 3 2 + 5 0, 1, 3, 4
FULL 1+2 0 + 3 and 1 + 4 2, 5
FULL 1+3 0 + 3 and 2 + 5 1, 4
FULL 2+3 1 + 4 and 2 + 5 0, 3
ALL FULL 0 + 3 and 1 + 4 and 2 + 5 none
IEC/IEEE-bus command SOUR:PDC:RCON AHAL
SELECT SLOT...
Selection of one of 6 possible slots. The number depends on the setting under
RATE CONFIGURATION. When selecting the slot, a window is opened in
which the data contents belonging to this slot can be defined. The content of
the window depends on whether an UPLINK or DOWNLINK was selected
under LINK DIRECTION. If the cursor is placed onto a slot in the diagram, it
may be switched on and off by pressing one of the unit keys (toggle function).
Menu selection: BURST TYPE = TCH
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
PDC
PHS
IS95
NADC
PDC
GSM
SLOT R P DATA SYNC CC SF SACCH DATA
0 DN 4 2 112 20 8 1 21 112
BURST TYPE... TCH
BURST STATE OFF ON
SET DEFAULT
SCRAMBLE STATE OFF ON
SCRAMBLE START 001 H
SUPER FRAME OFF ON
RCH POSITION 1
------------------BURST CONTENTS----------------
R0H
P2H
DATA PN9
SYNC 8 7A4B H
SYNC2 3 1BAF H
CC 00 H
SF 0 H
SACCH PN9
RCH PN9
-------------------CHANGE DATA------------------
SELECT DATA LIST... CURRENT: R&STDM
COPY CURRENT DATA LIST...
DELETE DATA LIST...
EDIT DATA LIST...
LEVEL
-30.0
dBm
PEP
-27.4
dBm
POWE
SLOT
SAVE
LINK
RATE
SELE
EDIT
0
TC
Fig. 2-191 Menu DIGITAL STD - PDC - SELECT SLOT, LINK DIRECTION DOWNLINK, SMIQ
equipped with Modulation Coder SMIQB20 and Data Generator SMIQB11