Digital Standard GSM/EDGE SMIQ
1125.5555.03 2.312 E-9
(SELECT SLOT...)
NORM
BURST TYPE
Opens a window for the selection of the burst type used to
configure the selected slot.
NORM Normal Burst
IEC/IEEE
:SOUR:GSM:SLOT2:TYPE NORM
SLOT LEVEL
Selection of level for selected slot.
OFF Maximum attenuation
IEC/IEEE
:SOUR:GSM:SLOT2:LEV OFF
FULL The level corresponds to the value indicated on
the SMIQ LEVEL display.
IEC/IEEE
:SOUR:GSM:SLOT2:LEV FULL
ATTEN The level is reduced by the value set under
SLOT ATTENUATION.
IEC/IEEE
:SOUR:GSM:SLOT2:LEV ATT
SET DEFAULT
Resets the subsequent parameters to the factory-set values.
IEC/IEEE-bus command
:SOUR:GSM:SLOT8:PRES
HOP TRIGGER
Switches the HOP trigger signal on or off. With ON selected,
a HOP signal will be generated at the end of the selected
slot. The signal is available at the HOP output of the
PARDATA connector. It can be used to perform a frequency
hop mode in the LIST MODE (see section 'List Mode').
IIEEE-bus command
SOUR:GSM:SLOT1:HOPP:TRIG
TAIL
Display of data contents in the 3 bit data field "Tail". The tail
bits are set to 000 according to the GSM standard.
DATA
Selection of data source for DATA fields. These fields are
regarded as a continuous field, i.e. a pseudo-random
sequence is fully continued from one DATA field to the next.
The following data sources are available:
PN.. PRBS data according to CCITT with periods
between 2
9
-1 and 2
23
-1.
IEC/IEEE
:SOUR:GSM:SLOT3:DATA PN15
DLIST Data from a programmable data list.
IEC/IEEE
:SOUR:GSM:SLOT3:DATA DLIS
SERDATA Data from data input SER DATA.
IEC/IEEE
:SOUR:GSM:SLOT3:DATA SDAT
S
Setting for the so-called "Stealing Flag". The selected setting
is valid for the two S fields.
IEC/IEEE-bus command
SOUR:GSM:SLOT2:SF 1
TSC...
Opens a window for selecting the so-called "Training
Sequence Code". A selection between 8 different training
sequences is possible.
IEC/IEEE-bus command
SOUR:GSM:SLOT2:TSC 0