SMIQ Digital Standard GSM/EDGE
1125.5555.03 E-92.313
(SELECT SLOT...)
NORM
EDIT
Input field for binary modifications of the
training sequence. A modified training
sequence is stored as a USER sequence
after a SAVE FRAME has been called up.
IEC/IEEE-bus command
SOUR:GSM:SLOT2:USER #B011011...
GUARD
Display of data content in the "Guard" field in binary form.
The length of the field is 8 bit in slots 1,2,3,5,6,7 and 9 bit in
slots 0 and 4. It is thus ensured that a frame has exactly
1250 bit as stipulated in the GSM standard.
SELECT DATA
LIST...
Opens a window for selecting a stored data list or for
generating a new list.
COPY CURRENT
DATA LIST TO...
Stores the current data list under a different name.
DELETE DATA
LIST...
Deletes a data list.
EDIT DATA
LIST...
Opens a window for editing a data list bit-by-bit. The
available storage capacity and the length of the current list is
displayed in parameters FREE and LEN (see also Section
List Editor).
COPY Copies a list range
FILL Fills the range with filler pattern
INSERT Inserts a list range at a different position of the
list
DELETE Deletes a list range
EDIT/VIEW Edits or views the list
Menu selection: BURST TYPE = DUMMY
Fig. 2-202 Menu DIGITAL STD - GSM/EDGE - SELECT SLOT - DUMMY, SMIQ equipped with
Modulation Coder SMIQB20 and Data Generator SMIQB11