Operating Instructions
Sartorius Moisture Analyzer
Model MA37
Electronic Moisture Analyzer
98648-019-93
98648-019-93
Question and Answer IconNeed help?

Do you have a question about the Sartorius MA37 and is the answer not in the manual?

Sartorius MA37 Specifications

General IconGeneral
BrandSartorius
ModelMA37
CategoryMeasuring Instruments
LanguageEnglish

Summary

User Information

Warning/Danger Symbols Used in these Instructions

Explains hazard symbols like WARNING!, CAUTION!, and IMPORTANT! used for safety warnings.

Safety Information

Guidelines and General Information

General compliance, user responsibility, and safety guidelines for analyzer operation.

Personal Protective Equipment

Details required protective clothing, glasses, and gloves for safe analyzer operation.

Danger of Explosion!

Warning about operating the analyzer in potentially explosive atmospheres.

Danger due to Fire or Explosion!

Specific advice for handling flammable or explosive substances during analysis.

Installation Instructions

Instructions related to faulty analyzer components and power supply connections.

Danger of Electric Shock!

Warning about the power supply cable and grounding conductor.

General View of the Equipment

Startup

Unpacking and Equipment Supplied

Instructions for unpacking the analyzer and checking its contents.

Setting Up the Analyzer

Steps to assemble the analyzer parts, including the pan support.

Choosing a Location

Guidance on selecting a suitable, stable, and safe place for the analyzer.

Power Connection (Power Supply)

Instructions and safety precautions for connecting the analyzer to a power source.

Basic Principles

Starting the Analysis

Steps to initiate a moisture analysis after setting parameters.

Operating the Moisture Analyzer

Switching the Analyzer On and Off (Standby)

Procedures for powering the analyzer on, off, and placing it in standby mode.

Menu

How to access and navigate the analyzer's main menu system.

System Settings (Setup Menu)

Opening the Menu and Changing the Settings

Steps to access and modify the analyzer's system settings.

Calibration/Adjustment

Settings for MA performance tests and weighing system adjustments.

USB port

Settings for data transfer to peripheral devices via USB.

Moisture Analysis

Customize parameters

Steps to modify parameters like heating program, end criteria, and result display.

Place pan and two filters, close hood for taring

Step to tare the sample pan with filters before analysis.

Performing the Moisture Analysis

Instructions for starting and executing a moisture analysis.

Fill in sample and close hood to start

Procedure for adding sample and starting the analysis.

Removing a Sample

Safe procedure for removing the hot sample pan after analysis.

Danger of poisoning or caustic burns!

Warnings for hazardous substances requiring handling in a laboratory hood.

Viewing and Changing Method Parameters

How to view and adjust analysis parameters for specific needs.

MA Performance Test

Starting the Performance Test

Steps to initiate a performance test for the analyzer.

Performance Test Procedure

Detailed steps for conducting the performance test with a reference sample.

Performance Test Measurement Not Successfully Completed

Actions to take when the performance test fails or is canceled.

Calibration and Adjustment

Weighing system adjustment

Steps for performing external calibration (CAL-Extern) of the weighing system.

Calibrating the Moisture Analyzer

Steps to begin the calibration process using an external weight.

USB Interface

Communication with Peripheral Devices

Overview of connecting to printers and PCs via USB for data exchange.

USB Connection as PC Keyboard

Using USB for PC keyboard emulation, including specific settings.

Direct Transfer of Data (PC)

Requirements and procedure for transferring data to a PC via USB.

Error Messages

Error Messages during Operation

Lists common error messages and their meanings during operation.

Problems

Common issues encountered during operation and their remedies.

Care and Maintenance

Service

Recommendations for regular servicing and technical safety inspections.

Cleaning the Bottom of the Sample Chamber

Procedures for safely cleaning the bottom of the sample chamber.

Removing the Sample Chamber Bottom

Step-by-step instructions for removing and cleaning the sample chamber bottom.

Repairs

Instructions regarding repair work to be carried out by trained technicians.

Cleaning the Heating Module

Detailed instructions for cleaning the analyzer's heating module.

Cleaning the Analyzer

General advice on cleaning the analyzer's control panel and housing.