Sartorius Mark 3 User Manual

Sartorius Mark 3
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Sartorius LMA100P, LMA110S
Model Mark 3
Electronic Moisture Analyzers
98648-016-12
98648-016-12

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sartorius Mark 3 and is the answer not in the manual?

Sartorius Mark 3 Specifications

General IconGeneral
Readability0.1 mg
Capacity220 g
Repeatability±0.1 mg
Linearity±0.2 mg
Stabilization Time2 seconds
Operating Humidity15% to 80% (non-condensing)
InterfaceRS-232

Summary

Warning and Safety Information

Class A Warning

Explains Class A product warning regarding potential radio interference in domestic environments.

Warning: Severe Burns!

Alerts users about potential severe burns from hot surfaces and components.

Safety Precautions

Warning

Notes the presence of a 3V Lithium Battery in the control module and its disposal requirements.

General Views of the Moisture Analyzer

Heater Module

Details the components of the heater module with numbered designations.

Control Module

Details the components of the control module with numbered designations.

Choosing a Suitable Location

Connecting the Moisture Analyzer to AC Power

Provides instructions for connecting the analyzer to AC power safely.

Operating Design

Keypad

Describes the main keypad, dedicated, numeric, and navigational keys.

Soft keys

Explains the dynamic function of soft keys based on display context.

Display Modes

Test

Details the test mode screen and operator guidance during testing.

Data Log

Describes how to review past test results for analysis.

Menu Structure

How to navigate in the menu structure

Explains how to select menus, drill down, and return to previous screens.

Operating the Moisture Analyzer

Functions available from the Standby screen

Lists actions that can be performed directly from the standby screen.

Testing a Sample

Caution

Warns about hot samples and handling them carefully with tweezers.

Setup Menu

Setting the Device Parameters in the Program Manage Menu

Guides on accessing and managing drying program parameters.

Time 1 and 2

Slope

Explains the slope function for automatic endpoint determination during tests.

Slope

Ideal Weight Percent Limit

Ideal Weight Lock

Prevents use of weights outside target limits.

Test Mode

LMA100P: Syringe

Describes the syringe mode for volatile samples on LMA100P.

Concentrate

Explains the concentrate mode for determining total suspended solids.

Data Log

To enter the data log

Guides on accessing the data log menu from the setup menu.

To view data log results

Guides on how to access and view stored test results.

Results Printout Format

To change the printout format

Guides on customizing the content of test result printouts.

Setting the Time and Date

To set the time and date (and format)

Guides on setting time, date, and format (12/24 hr).

Communication Ports

To set up serial communications to match peripheral device

Guides on configuring serial port settings for peripheral devices.

Security

Activate and Deactivate Security

Instructions for enabling and disabling the analyzer's security features.

To deactivate security

Steps to disable security protection by entering the pass code.

Setup Security Access

Guides on protecting specific features with a pass code.

Service

System

Displays analyzer information like model, software version, and calibration dates.

Calibration | Adjustment Functions

Calibrate Balance

Details procedures for calibrating the analyzer's balance.

Calibrate external

Guides on calibrating the balance using external weights.

Heater Adjustment

Adjust Temperature or Verify Temperature

Explains procedures for adjusting or verifying analyzer temperature.

To initiate an automatic temperature calibration and adjustment

Guides on performing automated temperature calibration.

To verify an adjustment temperature

Explains how to check the accuracy of adjusted temperatures.

Concentration Mode

To test samples in the Concentration mode

Details the steps for performing tests in concentration mode.

Syringe Mode (LMA100P only)

To test samples in the Syringe mode

Details the steps for performing tests in syringe mode.

Multi-module Mode

To test a sample in multi-mode

Guides on initiating tests for samples in multi-module operation.

Cleaning

Danger

Critical safety warning about disconnecting power before cleaning.

TGA Formulas (LMA100P)

To set the TGA parameters

Guides on configuring parameters for TGA analysis.