Readability | 0.1 mg |
---|---|
Capacity | 220 g |
Repeatability | ±0.1 mg |
Linearity | ±0.2 mg |
Stabilization Time | 2 seconds |
Operating Humidity | 15% to 80% (non-condensing) |
Interface | RS-232 |
Explains Class A product warning regarding potential radio interference in domestic environments.
Alerts users about potential severe burns from hot surfaces and components.
Notes the presence of a 3V Lithium Battery in the control module and its disposal requirements.
Details the components of the heater module with numbered designations.
Details the components of the control module with numbered designations.
Provides instructions for connecting the analyzer to AC power safely.
Describes the main keypad, dedicated, numeric, and navigational keys.
Explains the dynamic function of soft keys based on display context.
Details the test mode screen and operator guidance during testing.
Describes how to review past test results for analysis.
Explains how to select menus, drill down, and return to previous screens.
Lists actions that can be performed directly from the standby screen.
Warns about hot samples and handling them carefully with tweezers.
Guides on accessing and managing drying program parameters.
Explains the slope function for automatic endpoint determination during tests.
Prevents use of weights outside target limits.
Describes the syringe mode for volatile samples on LMA100P.
Explains the concentrate mode for determining total suspended solids.
Guides on accessing the data log menu from the setup menu.
Guides on how to access and view stored test results.
Guides on customizing the content of test result printouts.
Guides on setting time, date, and format (12/24 hr).
Guides on configuring serial port settings for peripheral devices.
Instructions for enabling and disabling the analyzer's security features.
Steps to disable security protection by entering the pass code.
Guides on protecting specific features with a pass code.
Displays analyzer information like model, software version, and calibration dates.
Details procedures for calibrating the analyzer's balance.
Guides on calibrating the balance using external weights.
Explains procedures for adjusting or verifying analyzer temperature.
Guides on performing automated temperature calibration.
Explains how to check the accuracy of adjusted temperatures.
Details the steps for performing tests in concentration mode.
Details the steps for performing tests in syringe mode.
Guides on initiating tests for samples in multi-module operation.
Critical safety warning about disconnecting power before cleaning.
Guides on configuring parameters for TGA analysis.