85/95
User manual SCAIME: NU-soft-eNod4B-E-0716_236704-C.doc
Nominal flow rate: Set point flow rate expressed in weight unit per time unit. eNod4 determines nominal belt
load from nominal speed and nominal flow rate.
Min permissible flow rate: Minimum value for flow rate for alarm function. Expressed in 0.1% of nominal flow
rate.
bits
Function
Note
bit b0
PID activation ON/OFF
0
PID function inhibited
In weigh feeder mode if batch option
1
PID function activated
bits b2 b1
feeder regulation function
01
Through materials flow
In weigh feeder mode
10
Through conveyor speed
bit b3
Batch activation ON/OFF
0
Batch dosing not activated
1
Batch dosing activated
bit b4
Clear totalization at start cycle option
0
Clear totalization at start cycle not activated
1
Clear totalization at start cycle activated
bit b5
Auto-stop conveyor at end batch
0
Auto-stop conveyor at end batch not activated
1
Auto-stop conveyor at end batch activated
bit b6
Dynamic zero auto-correction
0
Dynamic zero auto-correction not activated
1
Dynamic zero auto-correction activated
bit b7
Reserved(do not used)
/
/
bit b8
Totalization function if alarm occurred
0
Totalization continuously running if alarm occurred
1
Stop totalization function if alarm occurred
bit b9
Save Tare in non-volatile memory
0
Save tare in volatile memory (RAM)
1
Save tare in non-volatile memory (FRAM)
bit b10
Save Zero in non-volatile memory
0
Save zero in volatile memory (RAM)
1
Save zero in non-volatile memory (FRAM)
bits b15b11
Reserved
/
/