86/95
User manual SCAIME: NU-soft-eNod4B-E-0716_236704-C.doc
• Max permissible flow rate: Maximum value for flow rate for alarm function. Expressed in 0.1% of nominal flow
rate.
• Instant flow rate correction factor: Correction factor to apply after material test.
• Dynamic conveyor zero band: Defines limit values for dynamic zero correction function. Zero function is
cancelled when the weight is out of these limits.
• User fixed belt speed x100: Defines the belt speed in m/s if no speed sensor is connected to eNod4. The value
of 500 corresponds to 5 m/s.
• Weight section length: Represents the effective belt weigh frame length expressed in millimeters.
• Belt number of revolutions: Specifies the real belt revolutions to realize during speed/length calibrations and
dynamic zero procedure.
• Belt total length: Defines the total length of the belt in meters.
• Max permissible flow rate control output: Maximum value for control output for alarm function. Expressed in
0.1% of nominal flow rate.
• Min permissible flow rate control output: Minimum value for control output for alarm function. Expressed in
0.1% of nominal flow rate.
• Belt inclination x100: Defines the belt title angle in degrees. The value of 1500 corresponds with inclination of
15 degrees.
• Flow rate/belt load controls inhibit time at start: Monitoring the flow rate or belt load is only activated after
this delay time when the belt is started. It is expressed in second.
• Flow rate/belt load controls inhibit time in service: When the flow rate or belt load is below/above the
min/max value, the alarm is activated after this delay elapsed. It is expressed in second.
• Speed sensor maximum number of pulses per meter: Defines constant maximum pulses number of speed
sensor.
• Speed determination time factor: Specifies the belt speed determination time in multiple of 250ms.
• Nominal belt speed: Defines the nominal speed in m/s and the value of 500 corresponds to 5 m/s. eNod4
determines nominal belt load from nominal speed and nominal flow rate.
• Min permissible belt speed: Minimum value for belt speed for alarm function.
• Max permissible belt speed: Maximum value for belt speed for alarm function.
• Belt speed control inhibit time at start: Inhibition time at belt start of speed monitoring in second.
• Belt speed control inhibit time in service: Inhibition time in service of speed monitoring in second.
• Weight to totalize (Great WU): The main part of batch target in weight unit x1000.
• Complementary weight to totalize: The complementary part of batch target in weight unit.
• Weight to totalize inflight value: The batch target inflight value in weight unit.
• Calibration point n for the control output (output value): Expressed in 0.01% of maximum output current or
voltage. Up to 10 calibrations points can be configured. See calibration of flow rate section.
• Calibration point n of the control output (flow rate value): Expressed in weight unit per time unit. Up to 10
calibrations points can be configured. See calibration of flow rate section.
• Segments number for the Calibration curve of the control output: Defines calibration number of points of
flow rate and output value.