EasyManua.ls Logo

Scaime eNod4-B - Page 86

Default Icon
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
86/95
User manual SCAIME: NU-soft-eNod4B-E-0716_236704-C.doc
Max permissible flow rate: Maximum value for flow rate for alarm function. Expressed in 0.1% of nominal flow
rate.
Instant flow rate correction factor: Correction factor to apply after material test.
Dynamic conveyor zero band: Defines limit values for dynamic zero correction function. Zero function is
cancelled when the weight is out of these limits.
User fixed belt speed x100: Defines the belt speed in m/s if no speed sensor is connected to eNod4. The value
of 500 corresponds to 5 m/s.
Weight section length: Represents the effective belt weigh frame length expressed in millimeters.
Belt number of revolutions: Specifies the real belt revolutions to realize during speed/length calibrations and
dynamic zero procedure.
Belt total length: Defines the total length of the belt in meters.
Max permissible flow rate control output: Maximum value for control output for alarm function. Expressed in
0.1% of nominal flow rate.
Min permissible flow rate control output: Minimum value for control output for alarm function. Expressed in
0.1% of nominal flow rate.
Belt inclination x100: Defines the belt title angle in degrees. The value of 1500 corresponds with inclination of
15 degrees.
Flow rate/belt load controls inhibit time at start: Monitoring the flow rate or belt load is only activated after
this delay time when the belt is started. It is expressed in second.
Flow rate/belt load controls inhibit time in service: When the flow rate or belt load is below/above the
min/max value, the alarm is activated after this delay elapsed. It is expressed in second.
Speed sensor maximum number of pulses per meter: Defines constant maximum pulses number of speed
sensor.
Speed determination time factor: Specifies the belt speed determination time in multiple of 250ms.
Nominal belt speed: Defines the nominal speed in m/s and the value of 500 corresponds to 5 m/s. eNod4
determines nominal belt load from nominal speed and nominal flow rate.
Min permissible belt speed: Minimum value for belt speed for alarm function.
Max permissible belt speed: Maximum value for belt speed for alarm function.
Belt speed control inhibit time at start: Inhibition time at belt start of speed monitoring in second.
Belt speed control inhibit time in service: Inhibition time in service of speed monitoring in second.
Weight to totalize (Great WU): The main part of batch target in weight unit x1000.
Complementary weight to totalize: The complementary part of batch target in weight unit.
Weight to totalize inflight value: The batch target inflight value in weight unit.
Calibration point n for the control output (output value): Expressed in 0.01% of maximum output current or
voltage. Up to 10 calibrations points can be configured. See calibration of flow rate section.
Calibration point n of the control output (flow rate value): Expressed in weight unit per time unit. Up to 10
calibrations points can be configured. See calibration of flow rate section.
Segments number for the Calibration curve of the control output: Defines calibration number of points of
flow rate and output value.

Table of Contents

Other manuals for Scaime eNod4-B

Related product manuals