Operation
BAJR_USA_EN_V03 Page 4-3
4.3 Messages displayed when coffee machine is ready for operation
4.3.1 Display symbols with LEDs
Legend:
1 Temperature control display with green LED
- The machine is ready for operation. The green LED shows the optimum temperature has
been reached
2 Descaling control display with red LED
- Please contact an after-sales service technician authorized by the manufacturer
3 Malfunction/brewing unit control display with red LED
4 Grounds container control display with red LED
- The grounds container is missing, has not been inserted properly or is full
5
Coffee beans container control display with red LED
- The beans container is empty or an object has got stuck in the grinder
6 Water tank control display with red LED
- This display is inactive on this model
7 Display-text
- The upper half of the display will show messages concerning currently running operations
8 Display-symbols
- The lower half of the display will show one of the following symbols:
see 4.3.3 "Display messages - symbols" page 4-4.
Note:
See chapter 6 "Malfunctions" for rectification of any occurring problems.
4.3.2 Display messages - text
Note:
These messages will only appear when the coffee machine is idle, i.e. when no
beverages are being served. Displaying these messages does not mean that
the dispensing process will be interrupted.
Launch the cleaning program: see chapter 5 "Cleaning".
(Has the cleaning reminder been enabled by a service technician, 50 more
products can be served before the machine locks itself.)
Cleaning