9. Product Maintenance
SMF-MP10S User guide V1.1 Shanghai Seer Intelligent Technology Corporation 62
S/N Maintenance Content
Maintenance
Content
Criteria
Maintenance
Intervals
months
3.8
Inspect the shaft and
bearings of the drive
wheel for wear
Inspect visually Normal
Every month,
troubleshoot or
contact with
the
manufacturer
for assistance
Hydraulic System
4.1
Inspect for noise in the
pump station
Turn on the robot
normally, rise up
the fork, and hear
whether there is
any noise or
abnormal sound
near the pump
station accessories.
Normal
Every quarter,
find out the
reason for the
abnormal noise,
and replace the
pump station or
hydraulic oil
when
necessary.
4.2
Inspect the oil volume
of the oil tank and
replace the oil
Inspect with
reference to the
specific method for
maintenance. It is
recommended to
replace regularly
every 12 months.
Every half a
year
4.3
Clean the suction filter
element in the oil tank
It is recommended
to replace regularly
every 12 months.
Every half a
year
4.4
Clean up foreign
objects in the oil tank
It is recommended
to repla
ce the
hydraulic oil
regularly every 12
months.
Every half a
year
4.5
Inspect the valve block
for oil leakage
Inspect visually or
wipe the valve block
with clean tissue
(oil-absorbing
sheet).
Normal
Every month,
troubleshoot or
contact with
the
manufacturer
for assistance
4.6
Inspect the pipeline
joints for leakage,
looseness, cracks,
deformation, or
damage
Inspect visually: It is
recommended to
replace the seals
regularly every 12
months.
Normal Every month,
troubleshoot or
contact with
the
manufacturer
for assistance

Table of Contents