Stream ID entered to be received
Ignore TLS Certificate
Error
Do Not Ignore
Ignore
Defines whether to cease or continue
processing if TLS Certificate Error is signaled
Maximum Latency (ms)
30 10,000
Defines the maximum latency or buffer size
(in milliseconds)
Encryption Mode
Disabled
AES-128
AES-192
AES-256
Automatic
Defines which encryption standard to use or
if the OHP-IP-00 will automatically detect this
Encryption Key
User entry
The key to be used by downstream
decryption devices
FEC Overhead (%)
0 50
Defines the amount of static overhead to be
used to accommodate FEC
TS Packets Mode
Auto
Manual
In Auto mode, the source will define the
number of TS packets per Zixi packet.
In Manual mode, the user will define the
number of TS packets per Zixi packet.
TS Packets per Zixi
Packet
1 7
User defined value for when Manual mode is
enabled.
Bonding Mode
Disabled
All interfaces
One Interface
Any Interface
Specifies which interfaces, if any, are to be
set to bonding mode.
Interface Bonding Box
Available for One
Interface Mode
Any Interface Mode
Allows user to define parameters and details
about the port(s) when bonding
Zixi transmissions can be configured to use multiple interfaces simultaneously (Port
Bonding). By defining the maximum bitrate for that interface, the unit will only send up to
that rate on that interface. A Primary and Backup interface may also be chosen if
redundant links should be used.