Logs
Column Name
Description
Name
Defines the error message that will be provided if the instance is
detected.
Location
This shows the user the specific hardware or stream processing path
where the instance is detected.
Log
A checked box defines which instances will be recorded to the log file
Severity
A dropdown box within the row allows the user to define the instance
as an Error or Information event.
Alarm
A checked box defines which instances will raise an Alarm condition
on the unit. This will cause the Error LED on the front of the unit and in
the web client to illuminate.
SNMP Trap
A checked box defines which instances will trigger the OHP-IP-00 to
send trap messages.
The APPLY button at the bottom of the window will commit the settings changes to the
system, while the CANCEL button will ignore any settings changes and close the
configuration window.
Events
These instances are global to the system because they will have an impact on all
hardware and stream processing areas of the OHP-IP-00 module. These instances can
only be configured to be recorded in the log file and/or to be sent as SNMP Trap
messages.