70
Manual – Controllers DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
7
General technical data
Technical Data and Dimension Drawings
7 Technical Data and Dimension Drawings
7.1 General technical data
The general technical data listed in the following table applies to:
• DH.21B/41B option installed in the inverter
• DH.21B/41B/UOH.B stand-alone unit
General technical data
Interference immunity Meets EN 61800-3
Ambient temperature Installed in MOVIDRIVE
®
MDX61B:
• 0 °C to +60 °C
(Derating at 40 °C to 60 °C → System manual MOVIDRIVE
®
MDX60B/
61B)
Installed in MOVITRAC
®
B (AC 230 V; AC 400/500 V up to 4 kW):
• –10 °C to +60 °C
(Derating at 40 °C to 60 °C → System manual MOVITRAC
®
B)
Installed in MOVITRAC
®
B (AC 400/500 V over 4 kW):
• 0 °C to +60 °C
(Derating at 40 °C to 60 °C → System manual MOVITRAC
®
B)
Installed in the MOVIAXIS
®
master module:
• 0 °C to +45 °C
Compact controller:
• –10 °C to +60 °C
Climate class EN 60721-3-3, class 3K3
Storage temperature –25 °C to +70 °C
Climate class EN 60721-3-3, class 3K3
Type of cooling Convection cooling
Degree of protection IP20
Duty cycle Continuous duty
(see MOVIDRIVE
®
MDX60B/61B, MOVITRAC
®
B, MOVIAXIS
®
system
manuals)
Pollution class 2 according to IEC 60664-1 (VDE0110-1)
Installation altitude max. 4000 m (NN)