Manual – Controllers DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
5
Communication via Ethernet
Project Planning and Startup with MOVITOOLS
®
MotionStudio
8. For the engineering PC, enter an IP address that meets the following conditions:
In the blocks that define the network, the address segment for the engineering
PC must correspond to the other Ethernet stations.
In the blocks that define the station, the address segment for the engineering PC
must differ from the other stations.
The last block must not contain the values "0", "4", "127" or "255".
NOTE: In the IP address of the subnet mask (such as 255.255.255.0), the values
in the blocks have the following meaning:
"255", defines the address of the network where the stations are located.
"0", defines the address of the actual station to distinguish it from other
stations.
5.5.3 Configuring the communication channel via Ethernet
Do the following to configure a communication channel for Ethernet:
1. Click on "Configure communication connections" [1] in the toolbar.
This opens the "Configure communication connections" window.
2. From the list [1], select "Ethernet" as the communication type.
In the example, "ETHERNET" is activated as the communication type for the first
communication channel [2].
9007200388082827
[1] "Configure communication connections" icon
9007200399122315
[1] "Type of communication" dropdown menu
[2] "Activate" checkbox
[3] [Edit...] button
[1]
[1]
[2]
[3]
00