72
Manual – Controllers DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
7
DHE21B/41B option
Technical Data and Dimension Drawings
Ethernet 1 Fast system bus SBUS
Plus®
based on EtherCAT (with DH.41B)
Ethernet 2 • TCP/IP
• Connection options: Engineering PC, other controller, Intranet
USB USB 1.0 for connecting an engineering PC
RS485 interface COM1/2
X34:1–X34:6
• One DOP11B operator panel or one gearmotor with integrated MOVIMOT
®
frequency inverter can be
connected per RS485 interface.
• I/O standard, 57.6 / 9.6 kBaud, max. total cable length 200 m
• Dynamic terminating resistor with fixed installation
• COM 2 is electrically isolated from the DH.21B/41B option
SD memory cards
OMH41B-T0 – T25
OMC41B-T0 – T25
• PC-readable
•Includes:
–Firmware
– IEC program
–Data
• At least 128 MB memory
Engineering Engineering is carried out via the Ethernet 2 interface (X37) or USB interface (X35)
The engineering of any SEW components connected to the DHE21B/41B option can be carried out via
the DHE21B/41B option.
Engineering of option DHE21B/41B cannot be carried out via the inverters.
•MOVITOOLS
®
MotionStudio PC software with PLC Editor
DHE21B/41B option