Manual – IPOSplus®
141
12
P97x IPOS synchronization
P9xx IPOS Parameters
12.8 P97x IPOS synchronization
12.8.1 P970 DPRAM synchronization
Setting range: ON/OFF
MOVIDRIVE
®
B allows for synchronized operation with option cards (e.g. DHP11B,
DFE24B).
ON: Synchronized operation with option card is activated.
Important: The inverters may either be synchronized by SBus1, SBus2 or by DPRAM.
The inverters must not be synchronized from several interfaces at the same time.
SEW-EURODRIVE recommends to set P885/P895 to an identifier that is not used in the
entire CAN network. You need parameters P888 and P916 to implement synchroniza-
tion with interpolating setpoint processing.
OFF
: Synchronized operation with the option card is not activated.
12.8.2 P971 Synchronization phase
Setting range: −2–0
–2ms
Time interval between clock signal and data transfer