Manual – IPOSplus®
23
Communication commands
Assembler – Commands
Structure
23.5.6 SCOMST
This statement initializes the CAN interface, starts or stops the data reception and the
acyclic transmission of predefined data objects via SBus 1 or SBus 2. The data objects
re initialized via the SCOM function.
Regardless of the value for "X1", with MOVITRAC
®
B, the SCOMST X1 command al-
ways has the same effect as SCOMON (page 321).
Structure
Command structure
Mxxx SCOMON
Mxxx: Label (optional)
Argument Meaning
START ALL Starts cyclical communication synchronously from SBus 1 and SBus 2
STOP ALL Stops cyclical communication synchronously from SBus 1 and SBus 2
START1 Starts cyclical communication from SBus 1
STOP1 Stops cyclical communication from SBus 1
START2 Starts cyclical communication from SBus 2
STOP2 Stops cyclical communication from SBus 2
Command structure
Mxxx SCOMST X1
Mxxx: Label (optional)
X1: Argument
P
i
f
kVA
Hz
n
P
i
f
kVA
Hz
n