Technical specifications
Minimum Typical Maximum
s Sender unit
Test input
Input voltage
5)
HIGH (active) 11 V 24 V 30 V
Input current HIGH 7 mA 10 mA 20 mA
Switching voltage LOW
(inactive)
–30 V 0 V 5 V
Input current LOW
5)
–3.5 mA 0 mA 0.5 mA
Response time to test
Depending on the number of beams, maximum
150 ms
Wavelength of sender 950 nm
Power consumption 0.35 A
Weight Depending on protective field height (see page 50)
r Receiver unit
Switching outputs (OSSDs) 2 PNP semiconductor, short-circuit protected
6)
,
cross-circuit monitored
Response time
See chapter 10.2 on page 49
Switch off time 100 ms
Switch on time 2.5 × response
time
Switching voltage
7)
HIGH
(active, U
eff
)
15 V 24 V 28.8 V
Switching voltage
7)
LOW
(inactive)
0 V 0 V 2 V
Switching current 0 mA 500 mA
Leakage current
8)
0.25 mA
Load capacity
2.2 λF
Switching sequence
Depending on load inductance
Load inductance
9)
2.2 H
Test pulse data
10)
Test pulse width
120 λs 150 λs 300 λs
Test pulse rate
3 ¹/s 5 ¹/s 10 ¹/s
5)
As per IEC 61 131-2.
6)
Applies to the voltage range between –30 V and +30 V.
7)
As per IEC 61 131-2.
8)
In the case of a fault (0 V cable open circuit) the max. leakage current flows in the OSSD cable. The down-
stream controller must detect this status as LOW. A safe PLC (Programmable Logic Controller) must be able to
identify this status.
9)
The maximum rated load inductance is higher with lower switching sequence.
10)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers, make
sure that the test pulses do not result in deactivation when using the above parameters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Micro and is the answer not in the manual?

SICK C4000 Micro Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
Enclosure RatingIP65
Resolution14 mm
Supply Voltage24 V DC
SynchronizationOptical
ConnectionM12 connector
StandardsEN ISO 13849
Outputs2 safety outputs (OSSDs), 1 auxiliary output