Chapter 7 Operating Instructions
DME5000
92 © SICK AG • Germany • Subject to change without notice 8009813/ZJV1/2017-05
Menu Structure
Period Len
1 Type code 90H (default) Corresponding resolution 1 mm per period
2 Type code 91H Corresponding resolution 2 mm per period
4 Type code 92H Corresponding resolution 4 mm per period
8 Type code 93H Corresponding resolution 8 mm per period
16 Type code 94H Corresponding resolution 16 mm per period
For detailed description, see section 13.8 "Hiperface Interface".
RS-422
Mode
Request Data transfer on request only
Continuous Cyclic data transmission according to set baud rate
Protocol
Standard <STX>8122<[sign]><7*[0…9]><ETX>
CRLF <[sign]><7*[0…9]><CR><LF>
CP0 <[sign]><7*[0…9]>
CP1 Not assigned
For detailed description, see section 13.6 "RS-422 Interface".
DeviceNet
Baud rate
125 (default) Baud rate setting (125, 250, 500 kBd)
BusAddress
Addr. 06 (default) Setting of the DeviceNetaddress (area 0 … 63)
For detailed description, see section 13.7 "DeviceNet Interface".
Serial
Baud rate
19.2 (default) Baud rate for RS-422-interface (max. 115.2 kBd)
Baud rate for monitor interface via MF1 and MF2 (max.
38.44 kBd), only for DME5000 with SSI- or Hiperface
interface
For more detained description, see section 13.4
"Interface AdapterMonitor-Mode".
Data
7,e,1 7-data bit, even parity, 1 stop bit
8,e,1 8-data bit, even parity, 1 stop bit
8,n,1 (default) 8-data bit, no parity, 1 stop bit
Note
Note
Note

Table of Contents