7.15.7 Assigning a defined cut-off behavior
Overview
In a
monitoring case, you can assign a defined cut-off behavior to a cut-off path
instead of a field:
Always OFF: If the monitoring case becomes active, the cut-off path is in the OFF
state.
Always ON (NON-safe): If the monitoring case becomes active, a safety output in the
cut-off path is always in the OFF state. A non-safety output is always in the ON
state.
Always ON (safe): If the monitoring case becomes active, the cut-off path is in the ON
state.
Important information
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
The Always ON (safe) function has the same effect as a field which is always clear. In
a monitoring case with the Always ON (safe) function, the cut-off path containing this
function is permanently in the ON state.
Procedure
A
ssigning a defined cut-off behavior
Assign a cut-off behavior to a cut-off path in a monitoring case using drag-and-
drop.
Complementary information
If you have not assigned fields to certain cells in a monitoring case table, Safety
Designer automatically assigns the Always OFF function to these cells.
7.15.7.1 Configuring the default settings for defined cut-off behavior
Overview
W
ith this function, you can define specified cut-off behaviors per cut-off path as default
settings for monitoring cases.
Table 22: Show/hide preset for specified cutoff behavior
Show/hide preset for specified cutoff behavior
Procedure
1.
Select Show/hide preset for specified cutoff behavior.
Safety Designer displays an additional line in the monitoring case table.
2. Assign a cut-off behavior to a cut-off path in the Preset for specified cutoff behavior cell
using drag and drop.
Safety Designer applies the default settings when you add a new monitoring case.
7.15.8 Importing and exporting monitoring case tables
Overview
If you need identical monitoring case tables for different projects, you can export entire
monitoring case tables out of one project and import them into another project.